Loading Docks
LOADING DOCK SEALS & SHELTERS
Series TC300: Flexible Steel Dock Shelter
Services the Widest Variety of High Volume Traffic with
Varying Widths & Heights
Durable Frame of Double Kiln Dried Pressure Treated
Lumber at Rear, Galvanized Steel Tube Framing &
X-Arm Sides with Raked Header to Permit Drainage
Complete with Flexible Translucent Covering to Provide
Protection from the Elements & Admit Light
2 Added Layers of Fabric on Side Curtains Reinforce
Bottom & Prolong Life
Provides Full Unimpeded Access to Interior of Trailer
Yellow Guide Stripes to Assist Positioning of Trailers
Foam Bottom Draft Pads At Each Side Help Prevent Air
Flow Into the Loading Dock Area
Wide Selection of Highly Durable Fabrics & Wear
Surfaces to Maximize Durability
Steel Bumper Stop Assembly Protects the Shelter From
Misguided Trailers
Features
|
Specifications
Each
unit shall be constructed having the following minimum
dimensions: 11'-6" wide x 11'-0" high x 24" projection.
Side curtains to be reinforced with Max Flex™ multiply
bottom panels, equipped with a highly visible guide stripe.
Head curtain shall have Durapleat® overlapping panels at
each end and shall be stabilized by wind straps. Side curtain
edges shall encase a continuous closed cell neoprene cord.
The top sections of each side curtain to include a full “Z”
stay pattern. All curtains shall encase 3M “Scotch-Ply®”
stays (steel not acceptable) enclosed by multilayer
reinforcement sleeves. Stays to be spaced evenly with a
maximum of 14" O.C. in side curtains and a 20" maximum
O.C. in head curtain.
Shelter shall consist of yieldable head and side frames
constructed of: (3) three piece pressure treated wood rear
frames (kiln dried before and after treating) and a tubular
galvanized steel front frame and cross-arms; frame
construction shall provide for all joints and connections to be
continuous welded; having translucent material secured to
the exteriors and designed to yield under misdirected or
abnormal contact. Two structural steel bumper stops act as
limit stops on wall. The head frame shall be sloped from
center to provide for adequate drainage. Exterior frame
corners shall be trimmed with aluminum angle. One pair of
covered polyurethane foam bottom draft pads of a wedge
design to be furnished per shelter. All hardware shall be
galvanized steel..
Base Fabric: (in a variety of colors)
• Max Flex™ (heavy usage)
• Truk Flex™ (heavy usage)
• Rough Flex™ (medium usage)
• 22 oz. Vinyl (medium usage)
• 40 oz. Vinyl (medium/heavy usage)
Options
• Additional projections beyond 24" standard
• Tapered units |

|
|